Performance Prediction of the Diameter Effect Installed on Beside of Advancing Blade of the Savonius Water Turbine By using Myring equation for n = 2
Priyo Agus Setiawan, Mardi Santoso, Nopem Ariwiyono, Rini Indarti, Tri yogi Yuwono, Wawan Aries Widodo

Politeknik Perkapalan Negeri Surabaya


Abstract

Savonius have the smallest performance compared by the other turbine and the operational of Savonius at low TSR. In work, numerical analysis was done by using Savonius myring blade n=1 with ANSYS 17.0-Fluent. Flow analysis has been done by adding the circular cylinder. The ratio between the diameter of the cylinder and the turbine blade (ds/D) will be varied 0.2, 0.3, and 0.4. Installation of the circular cylinder with a horizontal distance (X/D) by 0.5 kept constant. The performance at ds/D of 0.4 with TSR number 1 have the highest performance in about 27.21%.

Keywords: Savonius vertical turbine, numerical study, CFD, myring

Topic: Engineering and Technology

CICo 2020 Conference | Conference Management System